燃?xì)獍l(fā)電機(jī)組降低噪聲有幾種方法

返回 2022.06.18 來源:http://www.51credits.cn 0
基于燃?xì)獍l(fā)電機(jī)組的工作原理,難以用降低聲源噪聲的方法來消聲,所以主要是要有效阻斷其噪聲傳播途徑。消聲技術(shù)的核心就是利用聲波在傳播中自然衰減的規(guī)律去縮小噪聲的污染面。具體降低噪聲的方法有以下幾種:
Based on the working principle of gas generator set, it is difficult to reduce the noise of sound source, so the main thing is to effectively block the noise transmission path. The core of noise elimination technology is to use the law of natural attenuation of sound waves in propagation to reduce the noise pollution surface. Specific noise reduction methods are as follows:
吸聲、隔聲及改變噪聲傳播方向。
Sound absorption, sound insulation and change of noise propagation direction.
在實(shí)際工程應(yīng)用中往往只用其中一種,本文采用三種方法并用的措施,針對燃?xì)獍l(fā)電機(jī)組提出了新型組合降噪技術(shù)。原來的消聲器以阻性消聲為主,功耗大,消聲效果不理想。經(jīng)仔細(xì)論證,應(yīng)用三級組合降噪技術(shù),將消聲器改造為新型組合式消聲器。
In practical engineering applications, only one of them is often used. In this paper, a new combined noise reduction technology for gas-fired generator units is proposed by using three methods. The original muffler mainly used resistive silencing, with high power consumption and unsatisfactory silencing effect. After careful demonstration, the muffler is transformed into a new type of combined muffler by using the three-stage combined noise reduction technology.
該組合式消聲器的主要組成部件有對噴消聲減振腔、多孔式消聲罩及吸聲隔熱層和吸聲共振板等。聲源通過一級的對噴消聲減振腔,可將中低頻聲源的噪聲能量充分進(jìn)行抗性耗散。
The main components of the combined muffler include a counter spray silencing and damping chamber, a porous silencing cover, a sound absorption and heat insulation layer, a sound absorption resonance plate, etc. The sound source can fully dissipate the noise energy of the medium and low frequency sound source through the first-class counter spray anechoic damping cavity.
改造規(guī)劃
Renovation planning
根據(jù)燃?xì)獍l(fā)電機(jī)組的作業(yè)原理,難以用下降聲源噪聲的方法來消聲,所以首要是要有用阻斷其噪聲傳達(dá)途徑。消聲技能的就是運(yùn)用聲波在傳達(dá)中自然衰減的規(guī)則去縮小噪聲的污染面。詳細(xì)下降噪聲的方法有以下幾種:吸聲、隔聲及改動噪聲傳達(dá)方向。在實(shí)踐工程運(yùn)用中往往只用其間一種,針對燃?xì)獍l(fā)電機(jī)組提出了新式組合降噪技能。
According to the operating principle of gas generator set, it is difficult to reduce the noise by reducing the noise source, so the first thing is to effectively block the noise transmission path. The center of silencing skill is to use the rule of natural attenuation of sound wave in transmission to reduce the pollution surface of noise. Detailed noise reduction methods include the following: sound absorption, sound insulation and changing the direction of noise transmission. In practical engineering application, only one of them is often used, and a new combined noise reduction skill is proposed for gas-fired generator sets.
燃?xì)獍l(fā)電機(jī)組
消聲排風(fēng)道
Silencing exhaust duct
電扇噪聲是由旋轉(zhuǎn)噪聲和渦流噪聲組成。旋轉(zhuǎn)噪聲由旋轉(zhuǎn)電扇葉片切開空氣流發(fā)生周期性擾動而引起。渦流噪聲是在旋轉(zhuǎn)葉片截面上發(fā)生邊界層別離時,氣體滑脫或割裂而成的一系列的漩渦流,然后輻射出一種非安穩(wěn)的活動噪聲。
Fan noise is composed of rotating noise and eddy current noise. The rotating noise is caused by the periodic disturbance of the air flow through the blades of the rotating electric fan. Vortex noise is a series of vortex flows formed by gas slippage or splitting when boundary layer separation occurs on the section of rotating blade, and then radiates a kind of unstable moving noise.
排風(fēng)道直接與外界相通,空氣流速很大,氣流噪聲、電扇噪聲和機(jī)械噪聲經(jīng)此通道輻射出去。為了操控電扇和排風(fēng)通道的噪聲,規(guī)劃了一個消音排風(fēng)道。這個消音排風(fēng)道長度較大,由導(dǎo)風(fēng)槽和排風(fēng)降噪腔組成。排風(fēng)降噪腔的作業(yè)原理,類似于阻性消聲器??山?jīng)過替換吸音資料(改動資料的吸音系數(shù)),改動吸音資料厚度、排風(fēng)通道長度和寬度等參數(shù)來提高消音效果。
The exhaust duct is directly connected with the outside world, and the air velocity is very large. The air flow noise, electric fan noise and mechanical noise are radiated through this channel. In order to control the noise of electric fan and exhaust duct, a silencing exhaust duct is planned. The silencing exhaust duct has a large length and is composed of an air guide slot and an exhaust noise reduction chamber. The operation principle of exhaust noise reduction chamber is similar to that of resistive muffler. The silencing effect can be improved by replacing the sound-absorbing data (changing the sound-absorbing coefficient of the data), changing the thickness of the sound-absorbing data, the length and width of the exhaust channel and other parameters.
以上就是今天為大家分享的關(guān)于問題的相關(guān)內(nèi)容,希望對大家能有所幫助,想要了解更多內(nèi)容可以電話聯(lián)系我們或者關(guān)注我們的網(wǎng)站http://www.51credits.cn。
The above is the relevant content about the problem shared for you today. I hope it can help you. If you want to know more, you can contact us by phone or follow our website http://www.51credits.cn 。
新聞搜索
濟(jì)南濟(jì)柴環(huán)能燃?xì)獍l(fā)電設(shè)備有限公司
  • 服務(wù)熱線

    0531-62325028
    0531-69951266

燃?xì)獍l(fā)電機(jī)組降低噪聲有幾種方法

基于燃?xì)獍l(fā)電機(jī)組的工作原理,難以用降低聲源噪聲的方法來消聲,所以主要是要有效阻斷其噪聲傳播途徑。消聲技術(shù)的核心就是利用聲波在傳播中自然衰減的規(guī)律去縮小噪聲的污染面。具體降低噪聲的方法有以下幾種:
Based on the working principle of gas generator set, it is difficult to reduce the noise of sound source, so the main thing is to effectively block the noise transmission path. The core of noise elimination technology is to use the law of natural attenuation of sound waves in propagation to reduce the noise pollution surface. Specific noise reduction methods are as follows:
吸聲、隔聲及改變噪聲傳播方向。
Sound absorption, sound insulation and change of noise propagation direction.
在實(shí)際工程應(yīng)用中往往只用其中一種,本文采用三種方法并用的措施,針對燃?xì)獍l(fā)電機(jī)組提出了新型組合降噪技術(shù)。原來的消聲器以阻性消聲為主,功耗大,消聲效果不理想。經(jīng)仔細(xì)論證,應(yīng)用三級組合降噪技術(shù),將消聲器改造為新型組合式消聲器。
In practical engineering applications, only one of them is often used. In this paper, a new combined noise reduction technology for gas-fired generator units is proposed by using three methods. The original muffler mainly used resistive silencing, with high power consumption and unsatisfactory silencing effect. After careful demonstration, the muffler is transformed into a new type of combined muffler by using the three-stage combined noise reduction technology.
該組合式消聲器的主要組成部件有對噴消聲減振腔、多孔式消聲罩及吸聲隔熱層和吸聲共振板等。聲源通過一級的對噴消聲減振腔,可將中低頻聲源的噪聲能量充分進(jìn)行抗性耗散。
The main components of the combined muffler include a counter spray silencing and damping chamber, a porous silencing cover, a sound absorption and heat insulation layer, a sound absorption resonance plate, etc. The sound source can fully dissipate the noise energy of the medium and low frequency sound source through the first-class counter spray anechoic damping cavity.
改造規(guī)劃
Renovation planning
根據(jù)燃?xì)獍l(fā)電機(jī)組的作業(yè)原理,難以用下降聲源噪聲的方法來消聲,所以首要是要有用阻斷其噪聲傳達(dá)途徑。消聲技能的就是運(yùn)用聲波在傳達(dá)中自然衰減的規(guī)則去縮小噪聲的污染面。詳細(xì)下降噪聲的方法有以下幾種:吸聲、隔聲及改動噪聲傳達(dá)方向。在實(shí)踐工程運(yùn)用中往往只用其間一種,針對燃?xì)獍l(fā)電機(jī)組提出了新式組合降噪技能。
According to the operating principle of gas generator set, it is difficult to reduce the noise by reducing the noise source, so the first thing is to effectively block the noise transmission path. The center of silencing skill is to use the rule of natural attenuation of sound wave in transmission to reduce the pollution surface of noise. Detailed noise reduction methods include the following: sound absorption, sound insulation and changing the direction of noise transmission. In practical engineering application, only one of them is often used, and a new combined noise reduction skill is proposed for gas-fired generator sets.
燃?xì)獍l(fā)電機(jī)組
消聲排風(fēng)道
Silencing exhaust duct
電扇噪聲是由旋轉(zhuǎn)噪聲和渦流噪聲組成。旋轉(zhuǎn)噪聲由旋轉(zhuǎn)電扇葉片切開空氣流發(fā)生周期性擾動而引起。渦流噪聲是在旋轉(zhuǎn)葉片截面上發(fā)生邊界層別離時,氣體滑脫或割裂而成的一系列的漩渦流,然后輻射出一種非安穩(wěn)的活動噪聲。
Fan noise is composed of rotating noise and eddy current noise. The rotating noise is caused by the periodic disturbance of the air flow through the blades of the rotating electric fan. Vortex noise is a series of vortex flows formed by gas slippage or splitting when boundary layer separation occurs on the section of rotating blade, and then radiates a kind of unstable moving noise.
排風(fēng)道直接與外界相通,空氣流速很大,氣流噪聲、電扇噪聲和機(jī)械噪聲經(jīng)此通道輻射出去。為了操控電扇和排風(fēng)通道的噪聲,規(guī)劃了一個消音排風(fēng)道。這個消音排風(fēng)道長度較大,由導(dǎo)風(fēng)槽和排風(fēng)降噪腔組成。排風(fēng)降噪腔的作業(yè)原理,類似于阻性消聲器。可經(jīng)過替換吸音資料(改動資料的吸音系數(shù)),改動吸音資料厚度、排風(fēng)通道長度和寬度等參數(shù)來提高消音效果。
The exhaust duct is directly connected with the outside world, and the air velocity is very large. The air flow noise, electric fan noise and mechanical noise are radiated through this channel. In order to control the noise of electric fan and exhaust duct, a silencing exhaust duct is planned. The silencing exhaust duct has a large length and is composed of an air guide slot and an exhaust noise reduction chamber. The operation principle of exhaust noise reduction chamber is similar to that of resistive muffler. The silencing effect can be improved by replacing the sound-absorbing data (changing the sound-absorbing coefficient of the data), changing the thickness of the sound-absorbing data, the length and width of the exhaust channel and other parameters.